
According to our investigation, the test syllabus of the CFPS exam is changing every year. Some new knowledge will be added into the annual real exam. Some old knowledge will be deleted. So you must have a clear understanding of the test syllabus of the CFPS study materials. Now, you can directly refer to our study materials. Our experts have carefully researched each part of the test syllabus of the CFPS Study Materials. Then they compile new questions and answers of the study materials according to the new knowledge parts.
Topic | Details |
---|---|
Topic 1 |
|
Topic 2 |
|
Topic 3 |
|
Topic 4 |
|
Topic 5 |
|
Topic 6 |
|
Our CFPS learning prep boosts the self-learning, self-evaluation, statistics report, timing and test stimulation functions and each function plays their own roles to help the clients learn comprehensively. The self-learning and self-evaluation functions of our CFPS guide materials help the clients check the results of their learning of the CFPS Study Materials. The timing function of our CFPS training quiz helps the learners to adjust their speed to answer the questions and keep alert and our study materials have set the timer.
NEW QUESTION # 138
Which type of plan review may provide information about a modification such as the removal of an abandoned underground flammable liquid tank?
Answer: A
Explanation:
An as built plan review is a type of plan review that may provide information about a modification such as the removal of an abandoned underground flammable liquid tank. An as built plan review is conducted after the construction or alteration of a building or system is completed and before the final approval or acceptance by the AHJ. An as built plan review verifies that the building or system conforms to the approved plans and specifications and complies with the applicable codes and standards. An as built plan review may also identify any changes or deviations from the original plans that occurred during the construction or alteration process, such as the removal of an underground tank. Reference:
NFPA 1: Fire Code, 2018 Edition, Section 1.12.8.1.1 1
Fire Protection Handbook, 20th Edition, Volume 1, Chapter 5, Section 5.2.3.4 2
NEW QUESTION # 139
Which type of construction consists of structural members of approved noncombustible or limited combustible materials with specified fire resistance ratings for exterior bearing walls of 3 or 4 hours?
Answer: C
Explanation:
Explanation
The correct answer is A. Type I construction consists of structural members of approved noncombustible or limited combustible materials with specified fire resistance ratings for exterior bearing walls of 3 or 4 hours.
This is the highest level of fire resistance among the five types of construction defined by NFPA 220: Standard for Types of Building Construction.Type I construction is typically used for high-rise buildings made of concrete and protected steel12
NEW QUESTION # 140
The removal of flammable vapors by displacement for cleaning a storage tank can be accomplished by displacement with air, inert gas and
Answer: A
Explanation:
Explanation
The removal of flammable vapors by displacement for cleaning a storage tank can be accomplished by displacement with air, inert gas, and water. Water is a common method of displacing flammable vapors from tanks, as it is readily available, inexpensive, and non-reactive with most fuels. Water can be sprayed into the tank to create a water seal that prevents the vapors from escaping and reduces the oxygen concentration in the tank. Water can also be used to rinse the tank walls and remove any residual fuel. However, water displacement may not be suitable for some tanks that contain water-sensitive or water-soluble fuels, or for tanks that have limited drainage or disposal facilities.
References:ust permanent closure requirements - Nevada;A Guide to Safety in Confined Spaces - CDC Stacks;Fire Explosion Prevention - Visual Encyclopedia of Chemical Engineering ...
NEW QUESTION # 141
The maximum distance between hangers for an automatic fire sprinkler system for a threaded lightwall steel pipe of 2 in. diameter is
Answer: D
Explanation:
According to NFPA 13, Table 17.4.2.1 (a), the maximum distance between hangers for an automatic fire sprinkler system for a threaded lightwall steel pipe of 2 in. diameter is 10 ft. This is done to ensure that there are not long stretches of unsecured piping that could sag, leak, or break. The distance between hangers may vary depending on the type of pipe, the type of hanger, and the seismic design category of the building. Reference: NFPA 13, Table 17.4.2.1 (a); Hangers and Support of Sprinkler System Piping | NFPA | NFPA.
NEW QUESTION # 142
Components in an exhaust system for commercial cooking installation include the ductwork, the exhaust fan, and the:
Answer: A
Explanation:
Provisions cover the design; installation; operation; and inspection, testing, and maintenance of the full spectrum of cooking equipment, hoods, grease removal devices, exhaust duct systems, fans, fire suppression systems, and clearance to combustibles.
NEW QUESTION # 143
......
The trouble can test a person's character. A bad situation can show special integrity. When to face of a difficult time, only the bravest people could take it easy. Are you a brave person? If you did not do the best preparation for your IT certification exam, can you take it easy? Yes, of course. Because you have ValidDumps's NFPA CFPS Exam Training materials. As long as you have it, any examination do not will knock you down.
CFPS Latest Test Preparation: https://www.validdumps.top/CFPS-exam-torrent.html
Tags: Training CFPS Solutions, CFPS Latest Test Preparation, CFPS Exam Dumps Pdf, CFPS Exam Practice, CFPS Test Dumps Free